Note:
See
“System
replaceable
units”
on
page
122
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Bus
fault
messages
FRU/action
Failure
reading
I2C
device.
Check
devices
on
bus
2.
v
System
board.
Failure
reading
I2C
device.
Check
devices
on
bus
3.
1.
Reseat
the
cable
between
the
SCSI
backplane
and
the
system
board
(see
“System-board
internal
connectors”
on
page
61.
2.
SCSI
backplane.
3.
Operator
information
panel.
4.
Power
supply.
5.
System
board.
Failure
reading
I2C
device.
Check
device
on
bus
4.
v
System
board
Undetermined
problems
Use
the
information
in
this
section
if
the
diagnostic
tests
did
not
identify
the
failure,
the
devices
list
is
incorrect,
or
the
system
is
inoperative.
Damaged
data
in
CMOS
memory
or
damaged
BIOS
code
can
cause
undetermined
problems.
To
reset
the
CMOS
data,
use
the
password
reset
jumper
to
override
the
power-on
password
and
clear
the
CMOS
memory;
see
“Erasing
a
lost
or
forgotten
password
(clearing
CMOS
memory)”
on
page
78.
If
you
suspect
that
the
BIOS
code
is
damaged,
see
“Recovering
the
BIOS
code”
on
page
77.
Check
the
LEDs
on
all
the
power
supplies
(see
“Hot-swap
power-supply
LED
errors”
on
page
96).
If
the
LEDs
indicate
the
power
supplies
are
working
correctly,
complete
the
following
steps:
1.
Turn
off
the
server.
2.
Be
sure
the
server
is
cabled
correctly.
3.
Remove
or
disconnect
the
following
devices
(one
at
a
time)
until
you
find
the
failure
(turn
on
the
server
and
reconfigure
each
time):
v
Any
external
devices
v
Surge
suppressor
device
(on
the
server)
v
Modem,
printer,
mouse,
or
non-IBM
devices
v
Each
adapter
v
Drives
v
Memory
modules
(minimum
requirement
=
two
256
MB
DIMMs)
Note:
Minimum
operating
requirements
are:
a.
Power
supply
b.
Power
backplane
c.
System
board
d.
One
microprocessor
and
VRM
e.
Memory
(with
a
minimum
of
two
256
MB
DIMMs)
f.
Front
operator
panel
g.
Two
fan
backplanes
4.
Turn
on
the
server.
If
the
problem
remains,
suspect
the
following
FRUs
in
the
order
listed:
v
Power
supply
v
System
board
Chapter
6.
Symptom-to-FRU
index
119
Содержание 88371RU
Страница 1: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 15: ...Server on off 8 to 80 Shipment 5 to 100 Chapter 1 General information 5...
Страница 22: ...12 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 24: ...14 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 92: ...82 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 149: ...Appendix B Safety information 139...
Страница 150: ...140 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 151: ...Appendix B Safety information 141...
Страница 152: ...142 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 153: ...Appendix B Safety information 143...
Страница 154: ...144 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 155: ...Appendix B Safety information 145...
Страница 165: ...Appendix B Safety information 155...
Страница 166: ...156 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 167: ...Appendix B Safety information 157...
Страница 168: ...158 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 172: ...162 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 185: ......
Страница 186: ...Part Number 25K8109 1P P N 25K8109...