1.
Read
Appendix
B,
“Safety
information,”
on
page
129
and
“Installation
guidelines”
on
page
15.
2.
Remove
the
filler
panel
for
the
drive
from
either
bay.
Note:
To
make
sure
there
is
adequate
system
cooling,
do
not
operate
the
server
for
more
than
2
minutes
without
either
a
hard
disk
drive
or
a
filler
panel
installed
in
each
bay.
3.
If
you
have
only
one
simple
swap
hard
disk
drive,
you
can
install
it
in
either
the
left
bay
or
the
right
bay.
4.
Insert
the
simple
swap
hard
disk
drive
into
the
drive
tray
assembly.
5.
Slide
the
drive
into
the
bay
until
the
rear
of
the
drive
snaps
into
place
with
the
rear
panel-mount
connector.
This
simple
swap
connector
contains
the
signal
and
power
connections
that
are
needed
by
the
SATA
drive.
6.
Install
the
filler
panel
for
the
drive.
7.
If
you
have
other
options
to
install,
install
them
now.
Otherwise,
go
to
“Completing
the
installation”
on
page
47.
Installing
and
removing
an
internal
DVD-ROM
drive
or
DVD-ROM
blank
bezel
The
following
notes
describe
the
type
of
DVD-ROM
drive
the
server
supports
and
other
information
that
you
must
consider
when
installing
a
DVD-ROM
drive:
v
The
server
supports
the
installation
of
an
optional
DVD-ROM
drive
only
when
you
are
using
a
3.5-inch
hard
disk
drive
configuration.
v
The
DVD-ROM
drive
must
be
a
slim
9.5
mm
drive
and
you
install
it
underneath
the
3.5-inch
hard
disk
drive,
on
the
left
side.
Note:
DVD-ROM,
CD-ROM
and
diskette
drives
can
also
be
attached
externally
using
the
USB
connector.
If
you
are
removing
an
internal
DVD-ROM
drive
or
blank
bezel,
continue
with
“Removing
an
internal
DVD-ROM
drive
or
DVD-ROM
blank
bezel”
on
page
29.
If
you
are
installing
an
internal
DVD-ROM
drive
or
blank
bezel,
go
to
“Installing
an
internal
DVD-ROM
drive”
on
page
31.
Removing
an
internal
DVD-ROM
drive
or
DVD-ROM
blank
bezel
Complete
the
following
steps
to
remove
an
internal
DVD-ROM
drive
or
DVD-ROM
blank
bezel:
1.
Read
Appendix
B,
“Safety
information,”
on
page
129
and
“Installation
guidelines”
on
page
15.
2.
Turn
off
the
server
and
peripheral
devices
and
disconnect
all
power
cords
and
external
cables
(see
“Turning
off
the
server”
on
page
10);
then,
remove
the
cover
(see
“Removing
the
cover”
on
page
18).
Chapter
3.
Customer
replaceable
units
29
Содержание 88371RU
Страница 1: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 15: ...Server on off 8 to 80 Shipment 5 to 100 Chapter 1 General information 5...
Страница 22: ...12 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 24: ...14 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 92: ...82 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 149: ...Appendix B Safety information 139...
Страница 150: ...140 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 151: ...Appendix B Safety information 141...
Страница 152: ...142 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 153: ...Appendix B Safety information 143...
Страница 154: ...144 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 155: ...Appendix B Safety information 145...
Страница 165: ...Appendix B Safety information 155...
Страница 166: ...156 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 167: ...Appendix B Safety information 157...
Страница 168: ...158 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 172: ...162 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 185: ......
Страница 186: ...Part Number 25K8109 1P P N 25K8109...