Software
error
symptoms
Note:
See
“System
replaceable
units”
on
page
122
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Symptom
FRU/action
Suspected
software
problem.
1.
To
determine
if
problems
are
caused
by
the
software,
verify
that:
v
The
server
has
the
minimum
memory
needed
to
use
the
software.
For
memory
requirements,
see
the
information
that
comes
with
the
software.
Note:
If
you
have
just
installed
an
adapter
or
memory,
you
might
have
a
memory
address
conflict.
v
The
software
is
designed
to
operate
on
the
server.
v
Other
software
works
on
the
server.
v
The
software
that
you
are
using
works
on
another
system.
If
you
received
any
error
messages
when
using
the
software
program,
see
the
information
that
comes
with
the
software
for
a
description
of
the
messages
and
suggested
solutions
to
the
problem.
2.
If
you
have
verified
these
items
and
the
problem
remains,
contact
the
place
of
purchase.
Service
processor
error
codes
When
viewed
in
the
system-error
log,
the
Remote
Supervisor
Adapter
II
SlimLine
messages
will
appear
as
text
descriptions.
To
determine
a
possible
error
condition
for
the
Remote
Supervisor
Adapter
II
SlimLine,
see
the
system-error
log
(see
“Viewing
the
system-error
log
from
diagnostic
programs”
on
page
70).
ServeRAID
error
codes
In
the
following
error
codes,
x
can
be
any
number
or
letter.
Note:
See
“System
replaceable
units”
on
page
122
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
1
xxx
(Microcode
checksum
error)
1.
ServeRAID
controller
2
xxx
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3000-31
XX
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3200
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
code
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3300
(ServeRAID-5i
only)
1.
Install
ServeRAID-5i
controller
in
an
extended
PCI
expansion
slot.
See
the
documentation
that
came
with
the
server
for
more
information.
Chapter
6.
Symptom-to-FRU
index
111
Содержание 88371RU
Страница 1: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 15: ...Server on off 8 to 80 Shipment 5 to 100 Chapter 1 General information 5...
Страница 22: ...12 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 24: ...14 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 92: ...82 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 149: ...Appendix B Safety information 139...
Страница 150: ...140 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 151: ...Appendix B Safety information 141...
Страница 152: ...142 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 153: ...Appendix B Safety information 143...
Страница 154: ...144 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 155: ...Appendix B Safety information 145...
Страница 165: ...Appendix B Safety information 155...
Страница 166: ...156 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 167: ...Appendix B Safety information 157...
Страница 168: ...158 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 172: ...162 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 185: ......
Страница 186: ...Part Number 25K8109 1P P N 25K8109...