Note:
See
“System
replaceable
units”
on
page
122
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
166-407-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test.)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
Operator
information
panel
cable.
4.
Operator
information
panel.
5.
System
board.
166-NNN-001
System
Management:
Failed
(BMC
indicates
failure
in
self
test
where
NNN=300
to
320.)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
System
board.
166-NNN-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test
where
NNN=400
to
420
(excluding
412,
414,
and
415).)
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Reflash
or
update
firmware
for
BMC.
3.
System
board.
180-197-000
(SCSI
ASPI
driver
not
installed)
1.
Remove
RAID
adapter,
if
installed,
and
rerun
test.
2.
System
board
180-361-003
(Failed
fan
LED
test)
1.
Fan
backplane
2.
Cable
(if
present)
from
fan
backplane
to
system
board
3.
System
board
180-XXX-000
(Diagnostics
LED
failure)
v
Run
diagnostics
panel
LED
test
for
the
failing
LED.
180-XXX-001
(Failed
front
LED
panel
test)
1.
Operator
information
card
2.
System
board
180-XXX-002
(Failed
diagnostics
LED
panel
test)
v
System
board
180-XXX-003
(Failed
system
board
LED
test)
v
System
board
180-XXX-005
(Failed
SCSI
backplane
LED
test)
1.
SCSI
backplane
2.
SCSI
backplane
cable
3.
System
board
201-XXX-0nn
(Failed
memory
test.)
Note:
nn
=
slot
number
of
failing
DIMM;
see
Figure
54
on
page
60.
1.
DIMM
nn
2.
System
board
201-XXX-n99
(Multiple
DIMM
failure,
see
error
text)
Note:
n
=
slot
number
of
failing
pair;
see
“Memory
module
considerations”
on
page
32.
1.
See
error
text
for
failing
DIMMs.
2.
Remove
the
lowest-numbered
DIMM
pair
of
those
that
are
identified
and
replace
it
with
an
identical
pair
of
known
good
DIMMs;
then,
restart
the
server.
Repeat
as
necessary.
If
the
failures
continue
after
all
identified
pairs
are
replaced,
go
to
step
4.
3.
Return
the
removed
DIMMs,
one
pair
at
a
time,
to
their
original
connectors,
restarting
the
server
after
each
pair,
until
a
pair
fails.
Replace
each
DIMM
in
the
failed
pair
with
an
identical
known
good
DIMM,
restarting
the
server
after
each
DIMM.
Replace
the
failed
DIMM.
Repeat
step
3
until
you
have
tested
all
removed
DIMMs.
4.
System
board.
Chapter
6.
Symptom-to-FRU
index
101
Содержание 88371RU
Страница 1: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 2: ......
Страница 3: ...xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 15: ...Server on off 8 to 80 Shipment 5 to 100 Chapter 1 General information 5...
Страница 22: ...12 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 24: ...14 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 92: ...82 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 149: ...Appendix B Safety information 139...
Страница 150: ...140 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 151: ...Appendix B Safety information 141...
Страница 152: ...142 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 153: ...Appendix B Safety information 143...
Страница 154: ...144 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 155: ...Appendix B Safety information 145...
Страница 165: ...Appendix B Safety information 155...
Страница 166: ...156 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 167: ...Appendix B Safety information 157...
Страница 168: ...158 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 172: ...162 xSeries 336 Type 1879 and Type 8837 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 185: ......
Страница 186: ...Part Number 25K8109 1P P N 25K8109...