If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 111.
Installing a SAS/SATA 4 Pac HDD option
If the server is a 12-drive-capable model with eight hard disk drive bays installed,
you can install an IBM System x3650 M2 Hot-swap SAS/SATA 4 Pac HDD option.
See http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of
supported optional devices. To order a SAS/SATA 4 Pac HDD option, contact your
IBM marketing representative or authorized reseller.
The SAS/SATA 4 Pac HDD option kit contains the following components:
v
One 2.5-inch hard disk drive backplane
v
Two SAS signal cables (one cable has a right-angle connector)
v
One internal power cable
v
One SAS expander card
v
Four hard disk drive bay filler panels
v
SAS controller front retention bracket
v
Remote battery cable, interposer card, and screw
To install a 4-disk-drive optional expansion device in a 12-drive-capable server
model, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 38.
2. Turn off the server and disconnect all power cords and external cables (see
“Turning off the server” on page 22).
3. Remove the server cover (see “Removing the cover” on page 44).
4. Remove the 4-drive filler panel that is to the right of drive bay 8, beneath the
IDs 8 - 11 on the front bezel.
5. To obtain more working room, remove fans 2 and 3 (see “Removing a
hot-swap fan” on page 91).
6. Pull the hard disk drives or fillers out of the server slightly to disengage them
from the backplanes. For more information, see“Removing a hard disk drive”
on page 60.
Chapter 2. Installing optional devices
65
Содержание 7947E3U
Страница 1: ......
Страница 2: ......
Страница 3: ...System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Страница 8: ...vi System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Страница 16: ...xiv System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Страница 40: ...24 System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Страница 150: ...134 System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Страница 162: ...Taiwan Class A compliance statement 146 System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Страница 168: ...152 System x3650 M2 Types 4199 and 7947 Installation and User s Guide...
Страница 169: ......
Страница 170: ...Part Number 81Y6111 Printed in USA 1P P N 81Y6111...