E-2
Operator Guide
Power-On Self-Test (POST) Indicators
20c
L2 cache POST error. (The display shows a solid 20c for 5 seconds.)
21c
L2 cache is not detected. (The display shows a solid 21c for 2 seconds.)
22c
Attempting a normal mode IPL from FDDI specified in NVRAM IPL device
list.
23c
Attempting a normal mode IPL from FDDI specified in IPL ROM device list.
24c
Attempting a service mode IPL from FDDI specified in NVRAM IPL device
list.
25c
Attempting a service mode IPL from FDDI specified in IPL ROM device list.
200
IPL attempted with keylock in the Secure position.
201
IPL ROM test failed or checkstop occurred (irrecoverable).
202
Unexpected machine check interrupt.
203
Unexpected data storage interrupt.
204
Unexpected instruction storage interrupt.
205
Unexpected external interrupt.
206
Unexpected alignment interrupt.
207
Unexpected program interrupt.
208
Unexpected floating point unavailable interrupt.
209
Unexpected SVC interrupt.
210
Unexpected SVC interrupt.
211
IPL ROM CRC comparison error (irrecoverable)
212
RAM POST memory configuration error or no memory found
(irrecoverable).
213
RAM POST failure (irrecoverable)
214
Power status register failed (irrecoverable).
215
A low-voltage condition is present (irrecoverable).
216
IPL ROM code being uncompressed into memory.
217
End of boot list encountered.
218
RAM POST is looking for 2M bytes of good memory.
219
RAM POST bit map is being generated.
220
IPL control block is being initialized.
221
NVRAM CRC comparison error during AIX IPL(key mode switch in Normal
mode). Reset NVRAM by reaccomplishing IPL in Service mode. For
systems with an internal, direct-bus-attached (DBA) disk, IPL ROM
attempted to perform an IPL from that disk before halting with this
three-digit display value.
222
Attempting a Normal mode IPL from Standard I/O planar-attached devices
specified in NVRAM IPL Devices List.
223
Attempting a Normal mode IPL from SCSI-attached devices specified in
NVRAM IPL Devices List.
224
Attempting a Normal mode IPL from 9333 subsystem device specified in
NVRAM IPL Devices List.
225
Attempting a Normal mode IPL from 7012 DBA disk-attached devices
specified in NVRAM IPL Devices List.
226
Attempting a Normal mode IPL from Ethernet specified in NVRAM IPL
Devices List.
227
Attempting a Normal mode IPL from Token Ring specified in NVRAM IPL
Devices List.
228
Attempting a Normal mode IPL from NVRAM expansion code.
229
Attempting a Normal mode IPL from NVRAM IPL Devices List; cannot IPL
from any of the listed devices, or there are no valid entries in the Devices
List.
Содержание 7013 J Series
Страница 1: ...7013 J Series Operator Guide SA23 2724 02 ...
Страница 12: ...xii Operator Guide ...
Страница 16: ...xvi Operator Guide ...
Страница 18: ...xviii Operator Guide ...
Страница 32: ...1 14 Operator Guide ...
Страница 80: ...2 48 Operator Guide ...
Страница 166: ...5 14 Operator Guide ...
Страница 186: ...7 4 Operator Guide ...
Страница 226: ...9 28 Operator Guide ...
Страница 258: ...B 8 Operator Guide ...
Страница 268: ...D 4 Operator Guide ...
Страница 297: ...Printed in the U S A SA23 2724 02 93H6489 ...