C-2
Operator Guide
The configuration of the tty1 for the S2 port looks similar to the following:
[TOP] [Entry Fields]
TTY tty1
TTY type tty
TTY interface rs232
Description Asynchronous
Terminal
Status Available
Location 00–00–S2–00
Parent adapter sa1
PORT number [s2]
Enable LOGIN disable
BAUD rate [9600]
PARITY [none]
BITS per character [8]
Number of STOP BITS [1]
TIME before advancing to next port setting [0]
TERMINAL type [dumb]
FLOW CONTROL to be used [rts]
OPEN DISCIPLINE to be used [dtropen]
STTY attributes for RUN time [hupcl,cread,brkint,
icrnl,opost,tab3,
onlcr,isig,icanon,
echo,echoe,echok,
echoctl,echoke,
imaxbel,iexten]
STTY attributes for LOGIN
[hupcl,cread,echoe,cs8,
ixon,ixoff]
LOGGER name []
STATUS of device at BOOT time [available]
TRANSMIT buffer count [16]
RECEIVE trigger level [3]
STREAMS modules to be pushed at OPEN time [ldterm,tioc]
INPUT map file [none]
OUTPUT map file [none]
CODESET map file [sbcs]
Flags and Parameters Settings
These are the minimum SystemGuard parameters/flags settings required for remote
support. These parameters can be displayed and changed through AIX with the mpcfg
command.
•
Modem configuration:
mpcfg –dm
Index Name Value
1 Modem Parameters File Name /usr/share/modems/7851
2 Service Line Speed 9600
3 Protocol Inter Data Block Delay 5
4 Protocol Time Out 60
5 Retry Number 2
6 Customer ID
7 Login ID
8 Password ID
Содержание 7013 J Series
Страница 1: ...7013 J Series Operator Guide SA23 2724 02 ...
Страница 12: ...xii Operator Guide ...
Страница 16: ...xvi Operator Guide ...
Страница 18: ...xviii Operator Guide ...
Страница 32: ...1 14 Operator Guide ...
Страница 80: ...2 48 Operator Guide ...
Страница 166: ...5 14 Operator Guide ...
Страница 186: ...7 4 Operator Guide ...
Страница 226: ...9 28 Operator Guide ...
Страница 258: ...B 8 Operator Guide ...
Страница 268: ...D 4 Operator Guide ...
Страница 297: ...Printed in the U S A SA23 2724 02 93H6489 ...