Service Guide
•
Enter
4
in the SET PARAMETERS menu to display the MISCELLANEOUS
PARAMETERS menu. The value set for all the flags, except
Fast IPL, is permanent until a
new change is made.
MISCELLANEOUS PARAMETERS
0> BUMP CONSOLE –> Present
1> AUTOSERVICE IPL –> Disabled
2> DIAL_OUT AUTHORIZATION –> Disabled
3> FAST IPL –> Disabled
4> SET MODE TO NORMAL WHEN BOOTING –> Enabled
5> BOOT MULTI–USER AIX IN SERVICE –> Disabled
6> SERVICE LINE SPEED –> 1200 Line speed
7> MAINTENANCE PASSWORD
8> CUSTOMER MAINTENANCE PASSWORD
9> ELECTRONIC MODE SWITCH FROM SERVICE LINE –> Disabled
SELECT [x:exit]:
BUMP Console Flag
Enables the use of a console on line S1 to display the
MAINTENANCE MENU. When disabled, the MAINTENANCE
MENU is not displayed on line S1.
1. Enter
0
to toggle this flag.
2. The new flag status (opposite of the previous state) immediately
takes affect and the system continues to boot.
Autoservice IPL Flag Enables the automatic bootstrap capability, allowing a boot to occur
even if the Mode Switch is in the Service position, thus avoiding the
MAINTENANCE MENU. When disabled, the MAINTENANCE
MENU is entered during the boot phase.
1. Enter
1
to toggle this flag.
2. The new flag status (opposite of the previous state) is displayed.
Dial-Out Authorization Flag
Enables automatic problem reporting to a remote service station
(with line S2) using the auto dial-out procedure. You can set the
dial-out phone numbers: see “Service Center Dial Out Phone
Number” on page 2-35. When disabled, problems are not
automatically reported to a remote service station.
1. Enter
2
to toggle this flag.
2. The new flag status (opposite of the previous state) is displayed.
Fast IPL Flag
Enables the bypass of the execution of extended POST at IPL time.
This flag is not permanent, and when set, is valid for the next
initialization only. It is automatically cleared during the next AIX boot
phase.
•
Enter
3
to enable this option.
Set Mode to Normal when Booting Flag
Enables the reset of the Electronic Mode Switch at boot time. When
enabled, the position is forced to Normal during each successful
boot.
1. Enter
4
to toggle this flag.
Содержание 7012 G Series
Страница 1: ...7012 G Series Service Guide...
Страница 6: ...vi Service Guide...
Страница 10: ...x Service Guide...
Страница 98: ...3 1520 8 Service Guide...
Страница 183: ...7 2 Service Guide Covers and Chassis 4 8 9 2 3 1 18 7 14 15 12 13 10 11 16 17 5 6...
Страница 185: ...7 4 Service Guide Electronics Drives and Power 1 of 2 22 23 4 5 6 7 8 9 11 12 19 18 14 15 1 2 3 21 17 16 13 20 10...
Страница 187: ...7 6 Service Guide Electronics Drives and Power 2 of 2 32 33 34 28 29 30 26 27 31 36 35 24 25 23...
Страница 264: ...Printed in the U S A SA23 2741 02 93H4875...