SystemGuard Remote Operation Configuration
C-1
Appendix C. SystemGuard Remote Operation
Configuration
In order to utilize the remote operation capabilities of SystemGuard and also allow console
mirroring, you need to have flags, parameters and tty configurations properly enabled.
Below, are tty0 and tty1 settings, sample modem files and all the parameters that are
necessary to allow remote operations.
Terminal Configuration
The configuration of the tty0 for the S1 port looks similar to the following:
[TOP] [Entry Fields]
TTY tty0
TTY type tty
TTY interface rs232
Description Asynchronous
Terminal
Status Available
Location 00–00–S1–00
Parent adapter sa0
PORT number [s1]
Enable LOGIN disable
BAUD rate [9600]
PARITY [none]
BITS per character [8]
Number of STOP BITS [1]
TIME before advancing to next port setting [0]
TERMINAL type [dumb]
FLOW CONTROL to be used [xon]
OPEN DISCIPLINE to be used [dtropen]
STTY attributes for RUN time [hupcl,cread,brkint,
icrnl,opost,tab3,
onlcr,isig,icanon,
echo,echoe,echok,
echoctl,echoke,
imaxbel,iexten]
STTY attributes for LOGIN [hupcl,cread,echoe,
cs8,ixon,ixoff]
LOGGER name []
STATUS of device at BOOT time [available]
TRANSMIT buffer count [16]
RECEIVE trigger level [3]
STREAMS modules to be pushed at OPEN time [ldterm,tioc]
INPUT map file [none]
OUTPUT map file [none]
CODESET map file [sbcs]
Содержание 7012 G Series
Страница 1: ...7012 G Series Service Guide...
Страница 6: ...vi Service Guide...
Страница 10: ...x Service Guide...
Страница 98: ...3 1520 8 Service Guide...
Страница 183: ...7 2 Service Guide Covers and Chassis 4 8 9 2 3 1 18 7 14 15 12 13 10 11 16 17 5 6...
Страница 185: ...7 4 Service Guide Electronics Drives and Power 1 of 2 22 23 4 5 6 7 8 9 11 12 19 18 14 15 1 2 3 21 17 16 13 20 10...
Страница 187: ...7 6 Service Guide Electronics Drives and Power 2 of 2 32 33 34 28 29 30 26 27 31 36 35 24 25 23...
Страница 264: ...Printed in the U S A SA23 2741 02 93H4875...