Using SystemGuard
2-23
•
Voltage Margins for CPUs, ASICs, and other components.
•
Device status information.
•
Options to select various types of devices.
DISPLAY CONFIGURATION – MAIN UNIT
MARGINS VALUE: +5 VOLT –> Normal
CPU (3.65 VOLT) –> Normal
ASIC (3.6 VOLT) –> Normal
SCSI DEVICES: Present –> #0A,#3A,#4A,#5A,#2A,#2B,#3B,#4B
Deconfigured –> #2B,#4B
PRESENT CPU: #0
PRESENT MC: #0
DETAILS: 0> IOC 4> OPP
1> SP 5> PS
2> CPU 6> SIB
3> MC 7> MCA
SELECT [Details (0–7) or x:exit]:
1. To see device-level information, enter menu device type number. The device level screen
for choice
0
(I/O card) is shown on page 2-24.
Note: If you select a device type and more than one device of the same type exists, you
are asked to provide a device number. For example, if you enter
2
for CPU devices,
and 2 such device boards exist, then you have to specify
CPU0
or
CPU1
when
requested.
2. Enter
x
to return to the system-level display configuration screen.
An expansion unit screen for unit 1 is shown below. It displays:
•
Unit serial number.
•
Device status information.
•
Options to select devices.
DISPLAY CONFIGURATION – UNIT 1
STATUS: Configured
BP SERIAL Nr.: 000ABCDE
(This field contains the serial
number of the expansion unit)
MARGINS VALUE: +5 VOLT –> Normal
SCSI DEVICES: Present –> #0A,#3A,#4A,#5A,#2A,#2B,#3B,#4B
Deconfigured –> #2B,#4B
DETAILS: 0> PS
1> SIB1
2> SIB2
SELECT [Details (0–2) or x:exit]:
Содержание 7012 G Series
Страница 1: ...7012 G Series Service Guide...
Страница 6: ...vi Service Guide...
Страница 10: ...x Service Guide...
Страница 98: ...3 1520 8 Service Guide...
Страница 183: ...7 2 Service Guide Covers and Chassis 4 8 9 2 3 1 18 7 14 15 12 13 10 11 16 17 5 6...
Страница 185: ...7 4 Service Guide Electronics Drives and Power 1 of 2 22 23 4 5 6 7 8 9 11 12 19 18 14 15 1 2 3 21 17 16 13 20 10...
Страница 187: ...7 6 Service Guide Electronics Drives and Power 2 of 2 32 33 34 28 29 30 26 27 31 36 35 24 25 23...
Страница 264: ...Printed in the U S A SA23 2741 02 93H4875...