Off Line Diagnostic Error Codes
D-21
Error
Number
Description
Failure
Percent
(%)
Failing
Function
Codes
Source
403-555
K
C59
C61
C63
50
25
25
Description: CPU to CPU interrupt.
XIRR register error.
Action: Use MAP 0210.
403-560
K
C59
C61
C63
50
25
25
Description: TOD to BUMP interrupt.
Unexpected interrupt error.
Action: Use MAP 0210.
403-561
K
C59
C61
C63
50
25
25
Description: TOD to BUMP interrupt.
No trap interrupt.
Action: Use MAP 0210.
403-563
K
C59
C61
C62
C63
C65
50
25
25
25
25
Description: TOD to BUMP interrupt.
MSR register error. BUMP interrupt management.
Action: Use MAP 0210.
403-565
K
Description: MCA to CPU interrupt.
All slots plugged with MCA boards.
Action: Use MAP 0210.
403-566
K
909
100
Description: MCA to CPU interrupt. LSA board not responding.
No interrupt on a PIO STORE with buid # on slot #.
Action: Use MAP 0210.
403-567
K
C62
C63
C65
C68
100
Description: MCA to CPU interrupt. No interrupt on a PIO
STORE with buid # on slot #.
Action: Use MAP 0210.
404-000
K
C63
C61
80
20
Description: Atomic instructions error.
Action: Use MAP 0210.
404-010
K
C63
C61
80
20
Description: Caches coherencies.
Concurrent coherent write accesses error.
Action: Use MAP 0210.
404-011
K
C63
C61
80
20
Description: Caches coherencies.
Concurrent not coherent write accesses error.
Action: Use MAP 0210.
404-012
K
C63
C61
80
20
Description: Caches coherencies.
DCBST from line owner error.
Action: Use MAP 0210.
404-013
K
C63
C61
80
20
Description: Caches coherencies.
DCBF from line owner error.
Action: Use MAP 0210.
404-014
K
C63
C61
80
20
Description: Caches coherencies.
DCBI from line owner error.
Action: Use MAP 0210.
404-015
K
C63
C61
80
20
Description: Caches coherencies.
Concurrent not coherent write accesses error.
Action: Use MAP 0210.
404-016
K
C63
C61
80
20
Description: Caches coherencies.
DCBST not from line owner error.
Action: Use MAP 0210.
404-017
K
C63
C61
80
20
Description: Caches coherencies.
DCBF not from line owner error.
Action: Use MAP 0210.
Содержание 7012 G Series
Страница 1: ...7012 G Series Service Guide...
Страница 6: ...vi Service Guide...
Страница 10: ...x Service Guide...
Страница 98: ...3 1520 8 Service Guide...
Страница 183: ...7 2 Service Guide Covers and Chassis 4 8 9 2 3 1 18 7 14 15 12 13 10 11 16 17 5 6...
Страница 185: ...7 4 Service Guide Electronics Drives and Power 1 of 2 22 23 4 5 6 7 8 9 11 12 19 18 14 15 1 2 3 21 17 16 13 20 10...
Страница 187: ...7 6 Service Guide Electronics Drives and Power 2 of 2 32 33 34 28 29 30 26 27 31 36 35 24 25 23...
Страница 264: ...Printed in the U S A SA23 2741 02 93H4875...