Assembly Instructions

Before you begin, please make sure all parts and proper quantities are included. (See Part Identifier Key) Any parts damaged during shipment must be reported 

within 24 hours of receipt. To report information regarding damages or if you have any questions, please call 800.242.2303.

Tools Required

•  4mm Allen 

wrench OR

•  4mm Hex bit
•  Drill extension
•  Phillips drill bit
•  Screw gun

 

•  #2 square bit

V080421 Version subject to change

Step 1:  

• 

Remove the two waste bins from the cabinet.

• 

Place the cabinet that has the totes in it upside down on a protected flat surface with it’s sub-bottom facing 

up.

 

(Upon installer’s discretion, remove doors (excluding trash door), shelving & totes before turning any of the 

cabinets over to lessen the weight of the cabinets.)

• 

Repeat above step for the other two base cabinets but when you’re placing it down on the protected surface, 

align the pre-drilled holes on the sides of all three cabinets with each other.

• 

NOTE: 

 

Please use the below image for the correct placement of each cabinet.

Images of these 

base cabinets 

are shown 

upside down in 

Steps 1-4.

Step 2: 

• 

With cabinets aligned together, place the 1/4”-20 x 30mm joint connector bolt w/ loctite through pre-drilled hole 

on the inside of one of the cabinets making sure bolt is pushed as far as it can go.   

• 

While holding the joint connector bolt flush to the cabinet, take a 1/4”-20x17mm joint connector nut and attach it 

to the end of the bolt (located in other base cabinet) turning it clockwise until it’s completely on.  Use a 4mm Allen 

wrench or 4mm hex bit and a screw gun to tighten as needed.

• 

Repeat 

Step 2 

with the remaining bolts and connector nuts so all three cabinets are attached together.

• 

NOTE: 

 

If you did not remove the totes or waste bins in 

Step 1

, you will need to remove them in order to gain 

access to the pre-drilled holes located inside of all three cabinets.

Содержание Nucleus Workstation

Страница 1: ...o lessen the weight of the cabinets Repeat above step for the other two base cabinets but when you re placing it down on the protected surface align the pre drilled holes on the sides of all three cabinets with each other NOTE Please use the below image for the correct placement of each cabinet Images of these base cabinets are shown upside down in Steps 1 4 Step 2 With cabinets aligned together p...

Страница 2: ...rts facing up Using 2 square bit attach caster base to the cabinets using 10 11 2 square drive flat head screws See image below pre drilled pilot holes are marked in red as an example for assembly instructions ONLY Step 4 Align caster with the threaded inserts Use the 1 4 20x25mm joint connector bolts to attach casters to the cabinet Repeat for the remaining casters See image below to see the loca...

Страница 3: ...hreaded insert of the top Use a 4mm Allen wrench or 4mm hex bit and a screw gun to fasten the bolt into place After the first bolt is fastened proceed attaching the remaining bolts in that cabinet 4 bolts per cabinet Repeat Step 6 for the other two cabinets If shelving doors totes and trash bins were removed place them back into place Step 7 Wire pulls are factory installed on the inside of doors ...

Страница 4: ... 0404229 1 4 20x17mm joint connector nut Used to attach 2 base cabinets together 8 040681 10 11 2 square drive flat head screw for wood Used to attach caster base to the 3 base cabinets 12 0400484 3 heavy duty plate casters w o brake 4 0400485 3 heavy duty plate casters w brake 2 04066947 1 4 20x25mm joint connector bolt black Used to apply casters 24 0406686 WO 1 4 20x35mm joint connector bolt bl...

Страница 5: ... a protected flat surface Align together the dog bone holes on both tops Step 2b Adjust Tite joint fastener to the size of the field joint opening and then place the fastener into each opening Using a 7 16 wrench tighten each fastener so that both tops are securely clamped together Step 3b Go back to Step 6 to finish assembling the Nucleus Workstation Part Description Qty 0406902 Tite joint fasten...