background image

 

 

SIMATIC IPC277D 19" INOX PRO, 

SIMATIC IFP1900 INOX PRO 

 

___________________ 
___________________ 
___________________ 
___________________ 
___________________ 
___________________ 
___________________ 

 

SIMATIC 

Industrial PC, Industrial monitor 

SIMATIC IPC277D 19" INOX PRO, 

SIMATIC IFP1900 INOX PRO 

Service Manual 

 

  

03/2015 

A5E35751762-AA 

Preface 

 

 

 

Overview 

 

 

Safety instructions 

 

 

Replacing the seal of the 

compartment cover 

 

 

Extended maintenance work 

 

 

Accessories and spare parts 

 

 

Technical support 

 

 

Содержание INOX PRO SIMATIC IPC277D

Страница 1: ...________ ___________________ ___________________ SIMATIC Industrial PC Industrial monitor SIMATIC IPC277D 19 INOX PRO SIMATIC IFP1900 INOX PRO Service Manual 03 2015 A5E35751762 AA Preface Overview 1 Safety instructions 2 Replacing the seal of the compartment cover 3 Extended maintenance work 4 Accessories and spare parts 5 Technical support A ...

Страница 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Страница 3: ...0 xxxx xxxx stands for the variant key of the article number Conventions The term device is also used instead of the product designation in this document Figures This document contains figures of the device described The figures can deviate from the particularities of the delivered device Steps in the figures are identified with process numbers according to the sequence in which they have to be ex...

Страница 4: ...placing the seal of the compartment cover 7 4 Extended maintenance work 9 4 1 Overview 10 4 2 Opening the device and loosening cables 12 4 3 Replacing the seal of the rear panel 14 4 4 Replacing operator controls 16 4 5 Changing the mounting type 19 4 6 Fastening the rear panel 21 5 Accessories and spare parts 23 A Technical support 25 A 1 Service and support 25 ...

Страница 5: ...ver with seal Illuminated pushbutton right with red LED Rear panel with seal EMERGENCY OFF button Mounting kit for support arm mounting Mounting kit for stand mounting This document describes the following maintenance work Replacing the seal of the compartment cover Replacing defective operator controls in the device front and LEDs Replacing the seal of the rear panel Changing the mounting type wh...

Страница 6: ... is closed If the seals are not inserted correctly during maintenance work or if the device is not closed properly IP66K degree of protection is no longer guaranteed Humidity may penetrate the device The result may be damage to the device and personal injury Make sure you follow the instructions in this document precisely when replacing the seals Make sure that the seals are inserted correctly and...

Страница 7: ...guaranteed Humidity may penetrate the device The result may be damage to the device and personal injury Make sure you follow the instructions in this document precisely when replacing the seal Make sure that the seal is inserted correctly and that the terminal compartment cover is fastened properly Requirement You need the service pack with article number 6AV7675 1JD20 0AA0 Procedure Note The desc...

Страница 8: ...in minor injuries or damages to the device Prevent the terminal compartment cover from dropping especially when it is mounted on a stand or support arm 3 Remove the seal of the terminal compartment cover 4 Insert the spare seal as shown in the figure 5 Check the seal for correct seat make sure that the bore holes of the seal enclose the collar of the press fit components see marked locations 6 Pla...

Страница 9: ...idity may penetrate the device This can result in personal injury or material damage Always replace the seal of the rear panel when you open the device Make sure you follow the instructions in this document precisely when replacing the seals Make sure that the seals are inserted correctly and that the covers are fastened properly NOTICE Placing the device on its front can damage operator controls ...

Страница 10: ...ents Avoid direct contact As a general rule do not touch electrostatic sensitive devices except in the case of unavoidable maintenance work Hold the modules at their edge so that you do not touch the connector pins or conductor paths This way the discharge energy does not reach and damage the sensitive components 4 1 Overview This section describes the following extended maintenance work Replacing...

Страница 11: ...ended maintenance work 4 1 Overview SIMATIC IPC277D 19 INOX PRO SIMATIC IFP1900 INOX PRO Service Manual 03 2015 A5E35751762 AA 11 Flowchart Perform the maintenance work according to the following flowchart ...

Страница 12: ...nection cables have been removed from the device interfaces Required tool Allen wrench size 8 mm Procedure 1 Place the device on its front Use a soft and elevated surface so that the front operator controls do not contact the working area and are not damaged 2 Remove the 20 screws that connect the rear panel with the device front 3 Lift the rear panel on the right and fold it back to the left as s...

Страница 13: ...ocking mechanisms A on the side of the plug and pull out the plug as shown in the figure below 5 Remove the adhesive tape X and loosen the plug of the touch cable from the front electronic To do so press the locking mechanism A of the plug and pull out the plug as shown in the figure below Save the adhesive tape 6 Remove the adhesive tape X and pull out the plug of the BLI cable from the front ele...

Страница 14: ... panel WARNING IP66K degree of protection The device has IP66K degree of protection when it is closed If the rear panel seal is not inserted correctly or if the device is not closed properly IP66K degree of protection is no longer guaranteed Humidity may penetrate the device The result may be damage to the device and personal injury Make sure you follow the instructions in this document precisely ...

Страница 15: ...the seal for correct seat especially that the bore holes of the seal enclose the collar of the press fit components Connecting the cables and closing the device Close the device when you are done with the maintenance work 1 Connect the cables between the front and the rear panel Perform steps 4 to 7 in the section Opening the device and loosening cables Page 12 in reverse order 2 Close the device ...

Страница 16: ...n Removing the EMERGENCY OFF pushbutton 1 Carefully turn the module of the EMERGENCY OFF pushbutton to the left until it unlocks 2 Remove the module from the EMERGENCY OFF pushbutton 3 Loosen the highlighted nut and remove the EMERGENCY OFF pushbutton Installing the EMERGENCY OFF pushbutton Proceed in the reverse order of the section Removing the EMERGENCY OFF pushbutton 1 Insert the new EMERGENCY...

Страница 17: ... module of the illuminated pushbutton you want to remove to the right until it is upright 2 Remove the module from the illuminated pushbutton 3 Loosen the highlighted nut and remove the illuminated pushbutton Replacing the LEDs of the illuminated pushbuttons 1 Remove the LED from its socket on the module 2 Insert the new LED Make sure that the 24V marking of the LED is aligned with the marking on ...

Страница 18: ...ut 1 5 Nm torque 3 Place the module on the illuminated pushbutton 4 Carefully turn the module to the left until you hear it click in place Connecting the cables and closing the device Close the device when you are done with the maintenance work 1 Connect the cables between the front and the rear panel Perform steps 4 to 7 in the section Opening the device and loosening cables Page 12 in reverse or...

Страница 19: ...ort arm device The conversion of a support arm device into a stand mounted device takes place in the same manner Procedure 1 Swap the position of the front and rear panel as shown in the figure below 2 Turn the rear panel by 180 3 Remove the adhesive tape X of the flat ribbon cable as shown in the figure below 4 Place the flat ribbon cable from the front on the rear panel and attach the adhesive t...

Страница 20: ...igure below 6 Connect the plug of the flat ribbon cable with the rear panel electronic Make sure that you do not reverse the polarity Secure the flat ribbon cable with a new piece of adhesive tape X 7 Connect the plugs of the LVDS display cable the touch cable and the BLI cable with the corresponding interface of the front electronic Secure the touch cable and the BLI cable with the adhesive tapes...

Страница 21: ...ng the rear panel When you are done with your maintenance work screw the rear panel to the front CAUTION IP66K degree of protection If the seal is not inserted correctly prior to fastening the rear panel or if the device is not screwed together properly IP66K degree of protection is no longer guaranteed Humidity may penetrate the device The result may be damage to the device and personal injury Ma...

Страница 22: ...1 Make sure that the seal is flush with the rear panel and does not protrude between rear panel and front 2 Screw in the four screws in the corners of the rear panel about halfway as shown in the figure below 3 If necessary correct the position of the rear panel 4 Screw in all 20 screws of the rear panel completely 5 Tighten the screws with a torque of 3 5 Nm ...

Страница 23: ...e device Mounting kit contents 1 stainless steel tube with flange Length 500 mm outer diameter 48 3 mm inner diameter 40 mm The mechanical interface of the stainless steel tube with flange fits the mechanical interface of the device 1 adapter support arm 8 hexagon screws M5 20 made of stainless steel 2 flat seals Article number 6AV7675 1GB10 0AA0 Service pack The service pack contains 1 spare seal...

Страница 24: ...ws for fastening the stainless steel tube with flange from a mounting kit to the mechanical interface of the device 1 connecting terminal for the power supply Documentation Article number 6AV7675 1JD21 0AA0 Spare parts The table below shows the order numbers of the operator controls on the front made by Schlegel http www schlegel biz Operator control Schlegel order number EMERGENCY OFF pushbutton ...

Страница 25: ... tech doku portal Your local representative http www automation siemens com mcms aspa db en Pages default aspx Training center http sitrain automation siemens com sitrainworld AppLang en Industry Mall https mall industry siemens com When contacting your local representative or Technical Support please have the following information at hand MLFB of the device BIOS version for industrial PC or image...