![IAI RoboNet Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/iai/robonet/robonet_operation-manual_604045081.webp)
61
Part 1 Specification
I/O Signal List
Signal type
Bit
Signal name Description Positioner
Simple
direct
Details
Current position
data
32-bit
data
-
Output as a hexadecimal number using a
32-bit signed integer (unit: 0.01 mm).
Example) To set +25.4 mm, specify
“0009EC” (decimal number: 2540).
z
The maximum settable value is +9999.99
mm = 999999 (decimal number) =
0F423FH (hexadecimal number).
z
Since a negative value is indicated as a 2’s
complement, the most significant bit
becomes “1.”
{
{
3.8.3
(4)
3.8.2 (12)
Completed
position number
b9-b0 PM***
The completed position number is read as a
binary number. A simple alarm code is output
while an alarm is present.
{
{
3.8.3 (3)
b15
EMGS
Emergency stop status
{
{
3.8.2 (2)
b14 CRDY
Controller
ready
{
{
3.8.2 (1)
b13
ZONE2
Zone output monitor 1
{
{
3.8.2 (13)
b12
ZONE1
Zone output monitor 2
{
{
b11
PZONE
Position zone output monitor
{
X
b10
MODES
Teaching mode status
{
X
3.8.2 (18)
b9
WEND
Position data load command status
{
X
3.8.2 (18)
b8-b6
-
Cannot be used.
-
-
-
b5
PSFL
Missed load in push operation
{
{
3.8.4 (1)
b4 SV
Ready
(servo
ON)
{
{
3.8.2 (5)
b3 ALM
Alarm
present
{
{
3.8.2 (3)
b2 MOVE
Moving
{
{
3.8.2 (8)
b1
HEND
Home return complete
{
{
3.8.2 (6)
PLC in
pu
t
Control signal
b0 PEND
Position
complete
{
{
3.8.2 (9)
{
: Available X: Not available
Содержание RoboNet
Страница 1: ...Operation Manual Forth Edition ROBONET ...
Страница 242: ...222 Part 1 Specification 5 4 3 External Dimensions 50 from DIN rail center 35 mm DIN rail 69 3 from DIN rail surface ...
Страница 257: ...237 Part 2 Startup Chapter X Installed face down X Installed face up ...
Страница 354: ...334 ...
Страница 395: ...375 ...
Страница 396: ...376 ...
Страница 397: ...377 ...