Part 1 Specification
(5) Error
Check
CRC check
Each message contains an error check field based on the CRC method.
The CRC field is used to check the content of the entire message. This check is independent of the parity check of
individual characters comprising the message.
The CRC field consists of two bytes of 16-bit binary data. The CRC value is calculated by the sender who appends the
CRC to the message. The recipient recalculates the CRC value while the message is being received, and compares the
calculated result against the actual value received in the CRC field. If the two values do not match, an error will be
recognized.
In CRC calculation, first the register is preloaded with all 16 bits set to “1.” Next, the successive 8-bit bytes are applied to
the current content of the register. Among the characters, only eight bits are used to generate a CRC. The start, stop and
parity bits are not used in CRC.
While a CRC is generated, each 8-bit character is compared against the register content based on the exclusive OR
gate.
The result is shifted toward the least significant digit, and zero is inserted in the most significant digit. Thereafter, the
least significant digit is taken out and checked. If the least significant digit is “1,” the register is again compared based on
the exclusive OR gate. If the least significant digit is “0,” the exclusive OR gate is not applied.
This process is repeated until the data is shifted eight times. After the last (eighth) shift, the next 8-bit byte is compared
against the current register value based on the exclusive OR gate. Then, this process is repeated eight times as
explained above. After the process has been applied to all message bytes, the last content of the register provides the
CRC value.
The generation polynomial is shown below (CRC-16 method)
x16 + x15 + x2 +1
When a CRC is appended to the message, the lower byte is appended first, followed by the upper byte.
(6) Send/Receive
Buffers
With the RS485 SIO GateWayR unit, the sizes of send/receive buffers are 160 bytes, respectively. Calculate the
message size to make sure the receive buffer is not exceeded in the case of messages sent from the host, and the send
buffer is not exceeded in the case of data request messages.
Содержание RoboNet
Страница 1: ...Operation Manual Forth Edition ROBONET ...
Страница 242: ...222 Part 1 Specification 5 4 3 External Dimensions 50 from DIN rail center 35 mm DIN rail 69 3 from DIN rail surface ...
Страница 257: ...237 Part 2 Startup Chapter X Installed face down X Installed face up ...
Страница 354: ...334 ...
Страница 395: ...375 ...
Страница 396: ...376 ...
Страница 397: ...377 ...