Part 2 Startup Chapter
Chapter 6 Setting for External SIO Link and Other
6.1 SCON/PCON-CF
Settings
and Signal Assignments
SCON controllers can be operated only in the positioner mode. They cannot be operated in the pulse-train input mode.
Set SCON as shown below.
(1) User
parameters
{
: Applicable
X: Not applicable
No. Name
Description
of
setting
(change)
SCON
PCON-CF
16
SIO baud rate
38400 bps (Default)
→
Change to 230400 bps.
{
{
17
Minimum delay for slave
transmitter activation
5 msec (Default)
→
Change to 2 msec.
{
{
18
PIO pattern selection
Default: 0 (Standard type)
→
Set a value between 0 and 3. *
{
{
19
PIO power monitoring
Default: 0 (Enable)
→
Change to 1 (Disable).
{
X
*
The maximum positions that can be registered varies depending on the PIO pattern.
(2) Piano switches (SCON Only)
Set piano switch 1 on the front panel of the SCON to the OFF position to change to the positioner mode.
(3) Mode
selector
switch
Set the mode selector switch on the front panel of the SCON/PCON-CF to MANU.
(4) Signal
assignment
The assignment of each signal for the SCON/PCON-CF is the same as with the RPCON/RACON. Refer to
“ROBONET Specification.”
(5) Set the axis number using the rotary switches.
Содержание RoboNet
Страница 1: ...Operation Manual Forth Edition ROBONET ...
Страница 242: ...222 Part 1 Specification 5 4 3 External Dimensions 50 from DIN rail center 35 mm DIN rail 69 3 from DIN rail surface ...
Страница 257: ...237 Part 2 Startup Chapter X Installed face down X Installed face up ...
Страница 354: ...334 ...
Страница 395: ...375 ...
Страница 396: ...376 ...
Страница 397: ...377 ...