![IAI RoboNet Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/iai/robonet/robonet_operation-manual_604045076.webp)
56
Part 1 Specification
[For Straight Slide Actuators]
Caution
Zone functions differ depending on the application version.
•
For application version V0015 or earlier, zone output is not performed for the setting below;
Zone s
≤
zone setting –
•
For application version V0016 or earlier, zone output is not performed for the setting below;
Zone s = zone setting –
Set value
Set value
Zone signal
output
Zone signal
output
Current
Position
Zone s : 70mm
Zone setting - : 30mm
Zone s : 30mm
Zone setting - : 70mm