Part 3 Maintenance
Alarms are classified into two levels based on the symptoms associated.
Alarm level
ALM lamp
ALM signal logic
Condition of generation
Reset method
Operation
cancellation
Lit “1”
After deceleration stop
Servo OFF
Input the alarm reset signal
(RES) from the PLC.
Perform a reset action from
the PC/teaching pendant.
Cold start
Lit
“1”
After deceleration stop
Servo OFF
Reconnect the power.
*
The ALM signal uses the positive logic.
After the power is turned on, this signal remains “0” while the system is normal, and turns “1” if an alarm has
occurred.
(Since the signal becomes “0” when the power is cut off, it cannot be used as an interlock signal.)
How to reset operation-cancellation alarms
Input the alarm reset (RES) signal for 6 msec or longer.
The ALM signal will return to “0” after the above period. Confirm the “0” status and then set the RES signal to “0”
(OFF).
Caution
Reset each alarm after identifying and removing its cause.
If the cause of the alarm cannot be removed, or the alarm cannot be reset even after its cause has been removed, contact
IAI.
If the same alarm generates again after a reset, the cause of the alarm has not been removed. In this case, repeating the
reset action may result in a burned motor or other undesired condition. Be sure to identify the cause and remove it before
resetting the alarm.
An alarm list for RACON and RPCON is provided on the next page.
Alarm reset (RES)
Alarm (ALM)
Alarm status
6 msec or longer
Alarm reset
Содержание RoboNet
Страница 1: ...Operation Manual Forth Edition ROBONET ...
Страница 242: ...222 Part 1 Specification 5 4 3 External Dimensions 50 from DIN rail center 35 mm DIN rail 69 3 from DIN rail surface ...
Страница 257: ...237 Part 2 Startup Chapter X Installed face down X Installed face up ...
Страница 354: ...334 ...
Страница 395: ...375 ...
Страница 396: ...376 ...
Страница 397: ...377 ...