(15) Jogging Speed/Inching Distance Switching (JVEL) PLC Output Signal
This signal switches between the parameter for specifying the jogging speed when jogging operation is selected and the
parameter for specifying the inching distance when inching operation is selected.
The relationships are summarized in the table below.
JVEL signal
Jogging operation: JISL = “0” (OFF)
Inching operation: JISL = “1” (ON)
“0” (OFF)
Parameter No. 26 (Jogging speed)
Parameter No. 26 (Jogging speed)
Parameter No. 48 (Inching distance)
“1” (ON)
Parameter No. 47 (Jogging speed 2)
Parameter No. 47 (Jogging speed 2)
Parameter No. 49 (Inching distance 2)
(16) Jogging/Inching Switching (JISL) PLC Output Signal
This signal is used to switch jogging operation and inching operation.
JISL = “0” (OFF): Jogging operation
JISL = “1” (ON): Inching operation
If the JISL signal switches to “1” (ON) during jogging operation, the actuator will decelerate to a stop and the inching
function will become effective. If the JISL signal switches to “0” (OFF) during inching operation, the actuator will
complete the inching operation and then the jogging function will become effective.
Jogging and inching operation commands are based on a combination of JISL, JVEL and JOG+/JOG- signals. The
relationships of these signals are summarized in the table below.
Jogging
operation
Inching
operation
JISL
“0” (OFF)
“1” (ON)
Speed
Parameter No. 26 (Jogging speed)
Parameter No. 26 (Jogging speed)
Travel distance
-
Parameter No. 48 (Inching distance)
JVEL=
“0” (OFF)
Acceleration/
deceleration
Rated value (The specific value varies
depending on the actuator.)
Rated value (The specific value varies
depending on the actuator.)
Speed
Parameter No. 47 (Jogging speed 2)
Parameter No. 47 (Jogging speed 2)
Travel distance
-
Parameter No. 49 (Inching distance 2)
JVEL=
“1” (ON)
Acceleration/
deceleration
Rated value (The specific value varies
depending on the actuator.)
Rated value (The specific value varies
depending on the actuator.)
Operation
When the JOG+/JOG- is “1”
When the JOG+/JOG- changes from
“0” from “1”
Содержание RoboNet
Страница 1: ...Operation Manual Forth Edition ROBONET ...
Страница 242: ...222 Part 1 Specification 5 4 3 External Dimensions 50 from DIN rail center 35 mm DIN rail 69 3 from DIN rail surface ...
Страница 257: ...237 Part 2 Startup Chapter X Installed face down X Installed face up ...
Страница 354: ...334 ...
Страница 395: ...375 ...
Страница 396: ...376 ...
Страница 397: ...377 ...