113
Part 1 Specification
(4) Message
Frame
Query and response messages use the following message frame.
Header Address Function Data Error
check
Trailer
T1-T2-T3-T4
8 bits
8 bits
N x 8 bits
16 bits
T1-T2-T3-T4
* “T1-T2-T3-T4” represents a silent interval.
[1] Header field
The frame starts with a silent interval of 3.5 characters or more.
[2] Address field
The address in the message frame. Fixed to 3FH for the RS485 SIO gateway.
[3] Function field
The following three functions can be used in the Modbus gateway mode.
Code (Hex)
Name
Function
Broadcast
support
03H
Read Holding Registers
Read holding registers
06H
Preset Single Register
Write holding register
{
10H
Preset Multiple Registers
Write multiple holding registers simultaneously
{
[4] Data field
This field is used to append data relating to the function code. The data field has a variable length and it can be
omitted.
[5] Error check field
16-bit data is indicated by two bytes of eight-bit data.
The error check result is calculated by the method called “CRC (Cyclical Redundancy Check).”
[6] Trailer field
The frame ends with a silent interval of 3.5 characters or more.
Содержание RoboNet
Страница 1: ...Operation Manual Forth Edition ROBONET ...
Страница 242: ...222 Part 1 Specification 5 4 3 External Dimensions 50 from DIN rail center 35 mm DIN rail 69 3 from DIN rail surface ...
Страница 257: ...237 Part 2 Startup Chapter X Installed face down X Installed face up ...
Страница 354: ...334 ...
Страница 395: ...375 ...
Страница 396: ...376 ...
Страница 397: ...377 ...