15
Rev. 161107
i3-TRNG-CAMS-Ax45RM_65RM-UM.indd
9. Connect the cabling to
the camera, including
RJ45 PoE/Network cable,
AC 24V cable (if using),
alarm and audio cables (if
using). Do not apply power
until the installation is
complete.
10. Re-attach the camera
to the back box. Use a
Use the
top conduit
opening to
route cabling
Use
sealant
Use
sealant
3/4” Electrical
EMT Conduit
Fitting
Rigid 3/4”
pipe
DB60
Gooseneck
Bracket
Phillips screwdriver to re-tighten
three silver screws attaching
camera to the back box.
11. Adjust the lens angle by rotating
and panning the camera lens
base. Lift off the camera liner for
easy lens position adjustment.
Do not over-rotate the camera
lens beyond the stop point to
avoid damage to the camera.
12. Once the desired view is
achieved, replace camera liner
until it snaps back into place.
Complete the Installation:
13. Replace the camera’s dome
bubble on top of the camera
module. Use the red dots on both
modules for easy alignment.
14. Use the supplied Torx bit to re-tighten
3 silver screws securing the dome
bubble housing to the camera module.
Remember to use sealant to maintain
IP67 rating in outdoor installations.