N700E INSTRUCTION MANUAL
4-9
Func-
code
Name
Run-
time
Edit
Description
Defaults
A09
External frequency start
pattern setting
X
Two options: select codes:
0--- start at start frequency
1--- start at 0Hz
0
A10
External frequency
sampling setting
X
Range n = 1 to 8, where n = number ofsamples for
average
4
Multi-speed Frequency Setting
A11
~
A25
Multi-speedfrequency
setting
O
Defines the first speed of a multi-speed profile,
range is 0 to maximum frequency(A04) in units
of 0.01Hz.
Setting range is 1-speed(A11) to 15-speed(A25).
Speed0:volume setting value
speed1:5Hz
speed2:10Hz
speed3:15Hz
speed4:20Hz
speed5:30Hz
speed6:40Hz
speed7:50Hz
speed8:60Hz
etc. 0Hz
A26 Jogging frequencysetting
O
Defines limited speed for jog, range is 0.5 to
10.00Hz in units of 0.01Hz.
The jogging frequency is provided safety
duringmanual operation.
0.50Hz
A27
Jogging stop operation
selection
X
Define how end of jog stops the motor:
three options:
0.... Free-run stop
1.... Deceleration stop(depending on
deceleration time)
2.... DC injection braking stop(necessary to set
DC injection braking)
0
V/F Characteristics
A28
Torque boost mode
selection
X
Two options: 0.... Manual torque boost
1.... Automatic torque boost
0
A29 Manual torqueboost setting
O
Can boost starting torque between 0 and50% above
normal V/F curve, from 0 to1/2 base frequency
Be aware that excessive torque boost can cause
motor damage and inverter trip.
1.0%