N700E INSTRUCTION MANUAL
10-2
Inverter Model
1100HF/
1320HFP
1320HF/
1600HFP
1600HF/
2000HFP
2200HF/
2500HFP
2800HF/
3200HFP
3500HF/
3800HFP
Max. Applicable motor
(4P, kW)
(Note1)
HD
110
132
160
220
280
350
ND
132
160
200
250
320
375
Rated
capacity
(kVA)
HD
380V
142.8
171.1
195
270
340
430
480V
180.4
216.2
230
315
400
500
ND
380V
159
204
245
305
390
460
480V
191
245
285
360
470
550
Rated input voltage
Three-phase 380~480V±10%, 50/60Hz±5%
Rated output voltage
(Note2)
Three-phase 380~480V (corresponding to input voltage)
Rated output current
(A)
HD
217
260
300
415
525
656
ND
230
285
370
450
600
680
Weight (Kg)
60
60
110
110
170
170
Protection Design
IP00
Footnotes for the preceding tables
Note 1. The applicable motor refers to HYUNDAI standard 3-phase motor(4-pole).
To use other motors, care must be taken to prevent the rated motor current(50/60Hz)
from exceeding the rated output current of the inverter.
Note 2. The output voltage decreases as the main supply voltage decreases (except for use of the AVR
function). In any case, the output voltage cannot exceed the input power supply voltage.
(3) Common specifications for 200V/400V class
Inverter model
Common specifications for all model
Control system
(Note3)
Space vector modulation PWM system
Output frequency range
(Note4)
0.01
∼
400Hz
Frequency accuracy
(Note5)
Digital command ±0.01% for Max. frequency, analog frequency ±0.1%
(25±10
℃
)
Frequency resolving power
Digital setting : 0.01HZ, Analog setting : Max. frequency / 1,000
Voltage/frequency
characteristic
V/f control (constant torque, reduced torque), free V/f control
Overload current rate
Heavy Duty(150%, 60sec), Normal Duty(120%, 60sec)
Acceleration/Deceleration
0.1
∼
3000.0 sec (Director, curve setting)
DC injection Braking
On starting and decelerating by stop command, inverter operates under
operation setting frequency. Or inverter operates with external input (Breaking
power, time, frequency can be set.)
In
p
u
t
S
ig
n
a
l
Frequency
Operator
Extend
signal
Setting by up/down key
Input voltage : DC0
∼
+10V (Input impedance 10KΩ)
Input current : 4
∼
20mA (Input impedance 200Ω)
Run/
Stop
Operator
Extend
signal
Run / Stop key (Forward / Reverse function mode)
Forward run / stop (1a connect, 1b selection possibility)
Intelligent input terminal
FW(Forward), RV(Reverse),
CF1~4(Multi-speed bit 1~4), RS(reset),
AT(Analog input current/voltage selection signal), USP(USP function)
EXT(external trip), FRS(free-run stop), JG(jogging),
SFT(software lock), 2CH(2
nd
acceleration), STA, STP, F/R(3-wire), UP,
DOWN(Up/down), O/R(Local Keypad Operation), T/R(Local Terminal Input
Operation), PIDIR(PID Integral Reset), PIDD(PID Disable)