N700E INSTRUCTION MANUAL
4-26
4.2.6
Expanded Function Mode of C Group
Func-
code
Name
Run-
time
Edit
Description
Defaults
Input Terminal Function
C01
Intelligent Input terminal 1
setting
X
Select function for terminal 1
<code> 0: Forward run command(FW)
1 : Reverse run command(RV)
2 : 1st multi-speed command(CF1)
3 : 2nd multi-speed command(CF2)
4 : 3rd multi-speed command(CF3)
5 : 4th multi-speed command(CF4)
6 : Jogging operation command(JG)
8 : 2-stage acceleration/deceleration command(2CH)
9 : Free-run stop command(FRS)
10 : External trip(EXT)
11 : Unattended start protection(USP)
12 : Software lock function(SFT)
13 : Analog input current/voltage selection signal(AT)
14 : Reset(RS)
15 : Start(STA)
16 : Keep(STP)
17 : Forward/reverse(F/R)
18 : Remote control UP(UP)
19 : Remote control DOWN(DOWN)
20 : Local Keypad Operation(O/R)
21 : Local Terminal Input Operation(T/R)
22 : PID Integral Reset(PIDIR)
23 : PID Disable(PIDD)
0
C02
Intelligent Input terminal 2
setting
X
Select function for terminal 2
<code>-see C01 parameter
1
C03
Intelligent Input terminal 3
setting
X
Select function for terminal 3
<code>-see C01 parameter
2
C04
Intelligent Input terminal 4
setting
X
Select function for terminal 4
<code>-see C01 parameter
3
C05
Intelligent Input terminal 5
setting
X
Select function for terminal 5
<code>-see C01 parameter
13
C06
Intelligent Input terminal 6
setting
X
Select function for terminal 6
<code>-see C01 parameter
14