N700E INSTRUCTION MANUAL
5-1
5. Using intelligent terminals
5.1
Intelligent terminal lists
Terminal
symbol
Terminal
name
Description
In
te
ll
ig
e
n
t
In
p
u
t
T
e
rm
in
a
l
(1
~
6
)
FW
(0)
Forward
RUN/STOP
terminal
SWF switch
ON(closed) :Forward
run
OFF(open) : stop
SWR switch
ON(closed) :Reverse
run
OFF(open) :stop
RV
(1)
Reverse
RUN/STOP
terminal
CF1
(2)
Multi-speed
frequency
commanding
terminal
1
CF2
(3)
2
CF3
(4)
3
CF4
(5)
4
JG
(6)
Jogging
Jogging operation
2CH
(8)
2-stage
acceleration
/deceleration
The acceleration or deceleration time is possible to change considering
the system.
FRS
(9)
Free-run stop
The inverter stops the output and the motor enters the free- run state.
(coasting)
EXT
(10)
External trip
It is possible to enter the external trip state
USP
(11)
Unattended start
prevention
Restart prevention when the power is turned on in the RUN state.
SFT
(12)
Terminal soft-
ware lock
The data of all the parameters and functions except the output frequency is
locked.
AT
(13)
Current input
selection
The [AT] terminal selects the inverter uses the voltage [O] or current [OI]
input terminals for external frequency control.
RS
(14)
Reset
If the inverter is in Trip Mode, the reset cancels the Trip Mode.
STA
(15)
Start
3-Wire input Start.
STP
(16)
Keep
3-Wire input Keep
F/R
(17)
Forward/Reverse 3-Wire input F/R.
UP
(18)
Remote control
UP
Remote control UP
DOWN
(19)
Remote control
DOWN
Remote control DOWN