Install the external heat exchanger
An external heat exchanger is an option for air-cooled pumps.
1.
Use the attached mounting bars to secure the heat exchanger to the ground or on an elevated platform.
2.
The heat exchanger includes 2 hydraulic hoses that are approximately 9 m (30 feet) long. Connect 1 end of each
hose to the top and bottom ports on the heat exchanger.
3.
Connect the 4-conductor cable from the external heat exchanger motor to the panel in the electrical enclosure.
The full load amperes, overload settings, and wire sizes are different, depending on the motor size.
For more information, refer to the electrical enclosure schematic.
Push the cable through the cord grip connector in the electrical enclosure. Connect the cable to the motor
starter–contactor.
Make the connections for remote operation
Remote operation is optional.
All controls are 24-volt direct current (DC).
These tables describe the remote connections from a user panel or a computer numerical control (CNC) operator
console.
Emergency stop
The OEM or the system integrator is responsible for connecting the emergency stop.
The terminals are in series with the emergency stop circuit. The terminals are wired to dry contacts on the emergency
stop at the remote control source.
If the pump is configured to run remotely and has a motion system (robot or cutting table), the emergency circuits from
the robot or cutting table can be in series with the local emergency stop circuit.
Make sure that there is a minimum clearance of 91 cm (36 inches) in the front and rear of the heat exchanger
to permit enough air flow for efficient cooling.
Wire number
Type of contact
Operation
5024A
Normally closed
Status
5024A
Normally closed
Discrete pressure input
6022, 6022A
Input, maintained, normally open
Remote mode active indicator
6027, 24COM
Output
Remote pump fault indicator
7004, 24COM
Output
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...