80
HyPrecision15/30/50
Operator
Manual 808240
5 – Preventive maintenance
Preventive maintenance
Repair the check valves
Repair the low-pressure poppets
Replace the low-pressure poppets after every 1,000 hours of operation.
Replace the check valve after every 2,000 hours of operation.
This procedure is for a moderately worn check valve. Severe wear requires replacement.
To reduce downtime, Hypertherm recommends doing preventive maintenance on both ends of the intensifier at the
same time.
Refer to the Parts lists section, which begins on page 147, for part numbers and ordering information.
Required tools, materials, and parts
12-micron lapping paper (included in the HyPrecision standard tool kit)
15-micron lapping paper (included in the HyPrecision standard tool kit)
Granite surface plate (included in the HyPrecision standard tool kit)
Clean, lint-free towel
Isopropyl alcohol
Masking tape
1.
Disassemble the intensifier to access the parts. Refer to page 104 for instructions.
2.
Tape a sheet of lapping paper on a granite surface block. Make sure that the paper is smooth and flat.
For best results, start with the 12-micron lapping paper and finish with the 15-micron lapping paper.
Repair or replace parts identified in the preventive maintenance schedule or if the parts show signs of
deterioration, corrosion, or damage.
Put the parts on a clean, dry, oil-free surface.
1
2
1
Check valve
2
Low-pressure poppet
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...