7.
Make sure that the motor turns in the direction shown by the arrow on the motor mount.
8.
If the pump has an optional external heat exchanger, make sure that the fan motor turns in the direction shown by the
arrow.
If the pump motor or the fan motor turns in the wrong direction, follow these instructions:
a.
Press the EMERGENCY STOP pushbutton.
b.
Disconnect the electrical power and trade 2 incoming leads on the primary circuit breaker inside the electrical
enclosure.
9.
Let the pump run for 2 to 3 minutes.
10.
Examine for leaks.
11.
Press the red buttons on the top of each of the filter housings to release air from the canisters. Hold the buttons
down until water comes out around the buttons.
12.
Press F1 on the operator interface to start the pump in running mode.
13.
Check the high-pressure water, low-pressure water, and hydraulic systems for leaks.
1
2
1
Shaft access cover
2
Motor direction arrow
HyPrecision 15 and 30
HyPrecision 50
1
2
1
2
1
Fan direction arrow
2
Airflow direction arrow
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...