HyPrecision15/30/50
Operator
Manual 808240
101
5 – Preventive maintenance
Preventive maintenance
Every 12,000 hours
Replace the spacer tubes
To reduce downtime, Hypertherm recommends doing preventive maintenance on both ends of the intensifier at the
same time.
Refer to the Parts lists section, which begins on page 147, for part numbers and ordering information.
Required tools, materials, and parts
11521 Spacer tube
1.
Disassemble the intensifier to access the parts. Refer to page 104 for instructions.
2.
Discard the used spacer tube.
3.
Install a new spacer tube.
4.
When all maintenance tasks are complete, reassemble the parts. Refer to page 111 for instructions.
Service the hydraulic center section
The hydraulic center section includes the pistons, plungers, hydraulic cylinder, hydraulic end caps, low-pressure seals,
and proximity switches.
Preventive maintenance on these parts requires special tools. Hypertherm Technical Service Associates are available to
supply information about maintenance, repair, and diagnostic support.
Repair or replace parts identified in the preventive maintenance schedule or if the parts show signs of
deterioration, corrosion, or damage.
Put the parts on a clean, dry, oil-free surface.
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...