HyPrecision15/30/50
Operator
Manual 808240
179
9 – Installation
In
st
allation
Seller obligations
If Hypertherm Inc. installs the equipment, some or all of these tasks are the responsibility of the Hypertherm technician as
defined in the sales agreement.
Make sure that the buyer understands all buyer obligations.
Make sure that the site is prepared for installation.
Make sure that all utility connections have been correctly routed.
Follow all setup and first-time startup instructions in this manual.
Supply training for maintenance and repair procedures.
Follow standard system acceptance tests.
Requirements
Location
Put the pump on a flat surface, such as concrete, that is capable of supporting the weight of the pump and thick enough
to resist vibration. The feet on the frame can be adjusted to level the pump.
Make sure that there is a minimum clearance of 91 cm (36 inches) on all sides of the pump to permit air movement for
efficient cooling and room for maintenance and repair.
Temperature
Ambient temperature has an effect on cooling. Supplementary cooling is usually necessary for a pump confined to a
small, high-temperature space.
For temperature requirements, refer to the Pump specifications section, which begins on page 165.
WARNING
Some locations can be hazardous if the atmosphere contains gas, vapors, or dust in explosive quantities.
Refer to requirements from the National Electric Code (NEC), the International Electrotechnical Commission
(IEC), and the Occupational Safety and Health Administration (OSHA), as well as local codes for detailed
information about environmental criteria.
CAUTION
When work must be done in confined spaces with limited access, the access must not be blocked by
ventilation ducts, hoses, pipes, or other equipment.
Do not install the pump in an environment where the temperature is below freezing. Freezing can cause
severe damage to low-pressure and high-pressure water parts.
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...