5 – Preventive maintenance
Preventive maintenance
Remove the high-pressure end cap
Required tools, materials, and parts
Clean, lint-free towel
Isopropyl alcohol
13/16-inch open-ended wrench (high-pressure water fitting)
7/8-inch open-ended wrench (low-pressure water fitting)
Square drive socket, 1-1/2 inch × 3/4 inch (stud nuts) (included in the HyPrecision standard tool kit)
1.
Disconnect the low-pressure water line.
2.
Disconnect the high-pressure water line.
3.
Remove the stud nuts.
4.
Pull the end cap off.
5.
Clean each part with a lint-free towel and isopropyl alcohol.
6.
Examine all parts for deterioration, corrosion, or damage.
7.
Clean and examine parts that will be replaced to identify wear patterns or damage that can signify other problems.
Do not use soap, detergent, or solvents.
1
2
3
4
1
Studs
2
Low-pressure water fitting
3
High-pressure end cap
4
Stud nuts
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...