HyPrecision15/30/50
Operator
Manual 808240
169
8 – Pump specifications
Pump speci
fications
All models
Hydraulic fluid
Operating conditions
If the cooling and cutting water temperature is higher than 23.9°C (75°F), cool the water before use. Water that is too
warm is inefficient for cooling and can reduce high-pressure seal life.
Cooling requirements
Refrigeration tons is the heat transfer required at 0°C (32°F) to make 1 short ton (2,000 lb) of ice in 24 hours.
4 kW = one refrigeration ton = 12,000 Btu/hour
Using a chiller with a water-glycol solution reduces the efficiency of the heat exchanger.
Type
• ISO viscosity grade (VG) 32 or 46 antiwear mineral oil
• synthetic hydraulic fluid
Tank capacity
151 L (40 gallons)
Maximum temperature
54.4°C (130°F)
Maximum pressure
Hydraulic pump pressure limit set at
the factory
217 bar or 21,718 kPa (3,150 psi)
Minimum
Maximum
Relative humidity
—
95%
Storage temperature
Water not drained
1.7°C (35°F)
—
Ambient operating temperature
4.4°C (40°F)
35.0°C (95°F)
HyPrecision pump model
kW
(minimum)
Refrigeration tons
(minimum tons)
Heat removal
requirement
(minimum Btu/hour)
15
3
0.83
10,000
30
6
1.67
20,000
50 and 50S
9
2.67
32,000
75S
14
4.00
48,000
100D
19
5.33
64,000
150D
28
8.00
96,000
Do not use glycol in a chiller at a concentration of more than 25%.
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...