HyPrecision15/30/50
Operator
Manual 808240
133
5 – Preventive maintenance
Preventive maintenance
Assemble the bleed-down valve
Required tools, materials, and parts
11328 On/off valve and bleed-down valve repair kit
11743 Bleed-down valve flow reducer
High-pressure antiseize lubricant such as Blue Goop or AccuGoop
1-inch open-ended wrench
3/4-inch open-ended crowfoot wrench or socket
Torque wrench
Cross-tip screwdriver
1.
Put high-pressure antiseize lubricant on the seat.
2.
Put the flow reducer into the outlet adapter.
3.
Put the seat into the outlet adapter.
4.
Install the outlet adapter in the bleed-down valve body. Torque the adapter to 27 N ∙ m (20 lbf ∙ ft).
Use 2 wrenches.
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a high-pressure
connection. Using only 1 wrench can increase bending stress to the parts and cause damage or premature
failure.
1
2
3
1
Outlet adapter
2
Flow reducer
3
Seat
Содержание HyPrecision 15
Страница 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Страница 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Страница 12: ...SC 12 Safety and compliance Warranty Warranty ...
Страница 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Страница 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Страница 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Страница 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Страница 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Страница 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Страница 146: ...146 HyPrecision15 30 50 Operator Manual 808240 5 Preventive maintenance Preventive maintenance ...
Страница 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Страница 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Страница 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...