background image

Jet Pump

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.

Description

These pumps are single stage domestic
water pumps designed for pumping
potable water. Shallow well pumps are
designed for applications where the
water level is less than 25 feet below
the pump. Flammable liquids such as
gasoline, chemicals, or corrosive liquids
should never be used with these
pumps.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or com-
ponents are damaged, return the unit
to the place of purchase for replace-
ment. Failure to do so could result in
serious injury or death.

Safety Guidelines

This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols. 

Danger indicates 
an imminently haz-

ardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially haz-

ardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a 

potentially haz-

ardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates 
important informa-

tion, that if not followed, may cause
damage to equipment.

Operating Instructions and Parts Manual

JSU50

General Safety
Information

1.  Read these rules and instructions

carefully. Failure to follow these
instructions could cause serious
bodily injury and/or property 
damage.

This pump is non-

submersible.

Install indoors

only.  Risk of elec-

trical shock.

Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not
use in a flammable and/or explosive
atmosphere. Personal injury and/or
property damage could result.

This pump is not 
designed to handle

salt water, brine, laundry discharge, or
any other application which may con-
tain caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will void 
warranty.

All wiring must be per-
formed by a qualified elec-
trician. The pump must be
installed in compliance with
the National Electrical Code and all
local codes.

2.  Connect this pump to a grounded

circuit equipped with a ground
fault interrupter device.

3.  Before installing this product, have

the electrical circuit checked by an
electrician to ensure proper 
grounding.

Pump must be disconnected
from power source before
installing or servicing.

311404-001  7/08

4. Be sure the water source and pip-

ing is clear of sand, dirt, and scale.
Debris will clog pump and void
warranty.

5.  Protect pump and piping from

freezing. Failure to protect from
freezing could cause severe dam-
age and will void the warranty.

6.  Follow priming instructions. Do not

run pump dry.

Installation

Protect pump from the elements by
installing in a basement, garage, tool
shed, or pump house. Install the pump
so the centerline of the pump is as
close as possible to the water level.
Keep installation area clear to provide
access for service and maintenance.
Protect the pump against flooding and
excess moisture.

Make sure the pump has adequate
ventilation. The surrounding tempera-
ture should not exceed 100˚F (38˚C) or
nuisance tripping of thermal overload
protector on the motor may occur.

PUMP PIPING INSTALLATION

Use new pipe for best results. Iron, 

To Water
Line

To
Well or
Cistern

Figure 1 - Pipe Installation

© 2008 Wayne Water Systems

For parts, product & service information

visit 

www.waynepumps.com

See Warranty on page 8 for important information about commercial use of this product.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Содержание JSU50

Страница 1: ...ater Do not pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flammable and or explosive atmosphere Personal injury and or property damage could result This pum...

Страница 2: ...o prime and or the tank to become water logged 7 Install a valve and an isolator hose between the tank and the house plumbing This will reduce the noise level of the pump system and aid in servicing 8...

Страница 3: ...and all applicable local codes The motor must be grounded by con necting a copper conductor to the grounding screw provided within the wiring compartment in the pressure switch The field wiring compar...

Страница 4: ...d during winter months or protected against freezing Protect the pipe from damage by swimmers and boaters Operation PRIMING PUMP Do not run pump dry Fill with water before starting motor Damage to pum...

Страница 5: ...50 100 200 300 JSU50 1 2 120 15 14 14 12 10 230 10 14 14 14 14 WIRING CHART RECOMMENDED WIRE AND FUSE SIZES Feet Friction Loss in 100 Feet of Plastic Pipe Gallons Per Minute Pipe Size 20 25 30 40 50...

Страница 6: ...or check valve stuck open 7 Improperly adjusted pressure switch 1 Turn power on or call power company 2 Replace fuse Reset breaker 3 Refer to wiring instructions Check and tighten all wiring 4 Replace...

Страница 7: ...7 JSU50 Operating Instructions and Parts Manual www waynepumps com Water Supplies Figure 11 Water Supplies...

Страница 8: ...re to operate in accordance with Wayne s written instructions THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED...

Страница 9: ...rage une cabane outils ou un b timent pour pompes Installer la pompe pour que la ligne centrale de la pompe soit aussi pr s que possible du niveau d eau Garder l endroit d installation libre d obstruc...

Страница 10: ...me compartiment Au plein le r servoir contient approximativement 2 3 eau et 1 3 d air comprim Ce type de r servoir requiert un contr le de volume d air qui remplace l air perdu Installation Suite pom...

Страница 11: ...de terre inutilis e et fixer la partie expos e du fil de terre entre la t te de vis et le corps du manostat puis resserrer Desserrer les deux vis sup rieures du manostat et resserrer avec les fils du...

Страница 12: ...le tuyau pendant l hiver ou le prot ger contre le gel Prot ger le tuyau contre le dommage caus par les nageurs et les bateaux Fonctionnement AMOR AGE DE LA POMPE Ne pas faire fonctionner la pompe au s...

Страница 13: ...4 Connecter nouveau la source d nergie lectrique Quand la pompe remplit le r servoir le contr le de volume d air fournit au r servoir la proportion correcte d air et d eau Ensuite la pompe s arr te l...

Страница 14: ...Sources d Eau Figure 11 Sources d Eau JSU50 Instructions d Utilisation et Manuel de Pi ces 14 Fr...

Страница 15: ...ifier et serrer tous les fils 4 Remplacer le manostat 5 Laisser refroidir Protecteur s enclenche automatiquement Fournir un endroit ombreux et bien ventil pour la pompe 1 Se r f rer aux instructions d...

Страница 16: ...aux instructions crit de Wayne IL N EXISTE AUCUNE AUTRE GARANTIE OU AFFIRMATION LES GARANTIES EXPRIM ES Y COMPRIS CELLES DE COMMERCIALISABILIT ET D ADAPTION UNE FONCTION PARTICULI RE SONT LIMIT ES UN...

Страница 17: ...tra aplicaci n que pueda contener sustancias qu micas c usticas y o materias extra as Podr a producirse da o en la bomba si se usa en estas aplicaciones invalidando la garant a Un electricista calific...

Страница 18: ...11 4 NPT No instale tuber as de succi n cerca de reas de nataci n TUBER AS DE DESCARGA FIGURA 2 Instale un conector en cruz de 19 1 mm 3 4 no incluido con la unidad en el orificio de salida de la bom...

Страница 19: ...l interruptor de circuito autom tico y el tama o del cable Instale y mantenga las conexiones de esta bomba de acuerdo al C digo Nacional de Electricidad y dem s c digos locales aplicables El motor deb...

Страница 20: ...la instalaci n de la bomba sta debe cebarse 1 Retire el tap n de cebado 2 Llene completamente la bomba y las tuber as con agua 3 Vuelva a colocar el tap n de cebado 4 Abra la llave para ventilar el si...

Страница 21: ...230 10 4 3 4 3 4 3 4 3 TABLA DE CONEXIONES TAMA OS RECOMENDABLES DE CABLES Y FUSIBLES Manual de Instrucciones de Operaci n y Piezas JSU50 Mantenimiento Continuaci n 2 Drene todas las tuber as hasta un...

Страница 22: ...Suministros de Agua Figura 11 Suministros de agua Manual de Instrucciones de Operaci n y Piezas JSU50 22 Sp...

Страница 23: ...2 Cambie el fusible Reajuste el interruptor autom tico 3 Rem tase a las instrucciones de conexiones Verifique y adjuste todas las conexiones 4 Cambie el interruptor 5 Deje enfriar La sobrecarga se rea...

Страница 24: ...o negligencia instalaci n inadecuada manten imiento inadecuado o funcionamiento sin seguir las instrucciones suministradas por escrito por la compa a Wayne NO HAY NINGUNA OTRA GARANTIA EXPRESA O IMPLI...