5 – Generator and Engine Components
7.
Unplug the 2 gray connectors near the engine block.
Figure 64
8.
Remove the wiring harness. Cut any cable ties necessary to free the harness.
Install the control system wiring harness
1.
With the new harness connect the J6, J4, and J3 wire connectors to the back of the system controller.
2.
Make the following connections.
Emergency stop contact block. See
Install the emergency stop contact block
ON/OFF power switch. See
Install the ON/OFF power switch
12 V circuit breaker. See
Install the 12 V circuit breaker
Alternator lamp. See
Fuel shutoff relay. See
Install the fuel shutoff relay
3.
Reconnect the diagnose plug.
4.
Reconnect the 2 gray connectors near the engine block.
5.
Secure the harness assembly with cable ties.
6.
Put the system’s top cover back in place. See
7.
Reconnect the negative (-) ground cable to the battery.
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...