Freedom 38 PPA
Service Manual
809010
35
1 – Troubleshooting
Common engine and generator issues
Problem
Solutions
The engine emits a lot of black smoke.
• Black smoke indicates a fuel-related issue. There is too much fuel in the
fuel system or not enough air.
• The engine is wet stacking and should be run under a heavy load. The
diesel engine is meant to operate optimally at moderate to heavy loads.
Running under a light load or no load for extended periods of time may
cause wet stacking or other engine damage. Do not idle the engine
longer than necessary.
• If the problem persists, have an authorized Deutz service dealer examine
the engine.
The engine emits blue smoke.
• In many cases, blue smoke indicates that the engine is burning oil. This
problem can be caused, or made worse, by using the wrong engine oil
and oil filter. Use only Deutz-brand oil and filters. Alternately, the
following oils from Shell can also be used: ROTELLA
®
T Triple
Protection
®
, ROTELLA T3, or ROTELLA T4 Triple Protection. See
• If the problem persists after changing the oil and filter, have an
authorized Deutz service dealer examine the engine.
The fuel filter gets clogged in cold
weather.
• If the fuel tank contains summer-grade fuel, the cold temperatures can
cause some of this fuel to “gel.” This thicker fuel can clog the fuel filter.
Add winter-grade diesel fuel to the fuel tank, and install a new
Deutz-brand fuel filter. See
Change the fuel filter in the engine
When you try to turn on the system, the
engine clicks but does not crank. Voltage
is present.
• Check the connections on the battery. Clean and tighten the connectors
• Jump-start or charge the battery. See page 32.
• Have an authorized Deutz service dealer examine the engine.
The 120 V auxiliary outlet is not working.
• Make sure the transformer circuit breaker on the front panel is turned
ON (
I
). This switch must be turned on before you can use the 120 V
auxiliary outlet.
• Test the GFCI protection on the 120 V auxiliary outlet. See page 66.
• If the outlet still does not work, it may be faulty. Replace the 120 V
auxiliary outlet.
The system controller LCD screen does
not display output current (amperage) for
the generator.
• Make sure the transformer circuit breaker on the front panel is turned
ON (
I
). This switch must be turned on in order to view the generator’s
output current on the system controller.
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...