Freedom 38 PPA
Service Manual
809010
23
1 – Troubleshooting
System faults triggered by predefined thresholds
Several preset thresholds are programmed into the system to define acceptable operating parameters.
When the system reaches a
warning
threshold:
A warning message displays.
The LED indicator illuminates solid
amber
.
You can continue to operate the system.
When the system reaches a
failure
threshold:
A fault message displays.
The LED indicator illuminates solid
red
.
The system shuts off.
The following table lists the conditions that trigger these warning and failure notifications and suggests how to clear each
fault:
Fault condition
Warning
threshold
System failure
threshold
Solutions
Air
compressor
overheated
None
110°C (230°F)
• Turn the system OFF, and allow the air compressor
components to cool.
• Make sure the air compressor has enough oil. See
• Change the oil and oil filter in the air compressor.
See page 78.
• Replace the temperature switch for the air
compressor. See page 167.
Crank failed
2 failed attempts
None
• This warning message displays when the system
fails to start the engine after 2 consecutive
attempts. See
High battery
voltage
15 V
None
• Turn the system OFF. Replace the battery. See
• If a new battery does not clear the fault, have an
authorized service dealer examine the alternator.
High engine
temperature
127°C (260°F)
129°C (265°F)
• Make sure the system has adequate ventilation. Do
not block the ventilation screens or louvers.
• Check engine oil level. See page 62.
• Change the oil and oil filter in the engine. See
• If the problem persists, have an authorized Deutz
service dealer examine the engine.
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...