Freedom 38 PPA
Service Manual
809010
185
6 – Air Compression Components
Replace the pressure relief valve on the separation tank
Remove the pressure relief valve on the separator tank
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Remove the plasma-side service panel.
3.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
4.
Drain the air tank to release pressure. See page 61.
5.
Release pressure from the separation tank by pulling the ring
on the pressure relief valve.
Figure 104
6.
Unscrew the pressure relief valve from the manifold.
Install the pressure relief valve on the separator tank
1.
Install the new pressure relief valve. Use part number 330116 thread sealant on the relief valve. Apply a thread seal
bead on 2–3 threads. Do not over-apply to avoid air line contamination.
2.
Reconnect the battery’s negative (-) ground cable.
3.
Replace the plasma-side service panel.
Kit number
Description
Kit: Manifold relief valve for the air compressor
1
1
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...