Freedom 38 PPA
Service Manual
809010
171
6 – Air Compression Components
Replace the air pressure gauge
Remove the air pressure gauge
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Drain the air tank to release pressure. See page 61.
3.
Remove the top cover from the system. See
4.
From behind the front panel, disconnect the air hose from the 90° fitting at the back of the air pressure gauge. Cut
any cable ties if necessary.
Figure 93
5.
Loosen the 2 screws in the bracket that secure the air pressure gauge to the front panel. The screws do not need to
be removed from the bracket. When loose the bracket can be removed with a twist.
6.
Remove the air pressure gauge from the front panel.
7.
Disconnect the 90° fitting from the back of the air pressure gauge.
Kit number
Description
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...