5 – Generator and Engine Components
Replace the automatic voltage regulator (AVR)
Remove the AVR
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the on-board plasma supply to gain access to the AVR. See
When the plasma supply is removed, you can access the AVR through that opening in
the front panel.
4.
Remove the cover panel from the AVR. See
.
5.
Remove the 4 screws that secure the AVR.
6.
Disconnect the 4 wire connections from the top of the AVR.
7.
Remove the AVR from the alternator.
Figure 57
Kit number
Description
Kit: Automatic voltage regulator (AVR) for generator/alternator, 480 VAC
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...