6 – Air Compression Components
Replace the ball valve, elbow fitting, and elbow coupler on the separation tank
Remove the ball valve, elbow fitting, and elbow coupler on the separation tank
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Drain the air tank to release pressure. See page 61.
4.
Release pressure from the separation tank by pulling the ring on the pressure relief valve. See
5.
Remove the top cover and plasma-side panel from the system. See
6.
Drain the oil from the separation tank. See page 79.
7.
Remove the drain hose from the elbow fitting attached to the ball valve.
8.
Loosen and remove the large hose clamp around the separation tank. Remove 2 bolts and washers that secure the
tank to the system chassis. The tank can be moved to access the ball valve, elbow fitting, and elbow coupler. See
9.
Disconnect the ball valve from the two elbow fittings.
Kit number
Description
Kit: Ball valve for air compressor
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...