26
Freedom 38 PPA
Service Manual
809010
1 – Troubleshooting
171
12
The electronic control unit is too hot
or too cold.
• Turn OFF the system. Allow the system to cool. Turn
ON the system. If the fault persists, have an
authorized Deutz service dealer examine the engine.
190
0 or 8
Engine speed warning. The engine is
running too far under or over
1800 RPMs.
• An under speed issue can be triggered by a low fuel
level. Add clean, low-sulfur diesel fuel. Do not
overfill the fuel tank.
• Have an authorized Deutz service dealer examine
the engine.
231
12, 9, or
14
Controller area network (CAN) bus
communication fault.
• Have an authorized Deutz service dealer examine
the engine.
240, 253,
or 254
2 or 12
Program logic or memory fault.
• Turn OFF the system, then turn ON the system. If
the fault persists, have an authorized Deutz service
dealer examine the engine.
524287
31
No fault present.
• No active faults are still present. Reset the control
system if needed. See page 21.
SPN
FMI
Description
Solutions
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...