5 – Generator and Engine Components
11.
Remove the 4 engine relays, then unscrew the relay housings from the bracket.
Figure 71
12.
Lift the protective red cover from the circuit breaker located next to the relay housings. Disconnect the single red
wire
and the double red wire
harness connections.
13.
Disconnect the red
and blue
wires connected to the alternator.
Figure 72 – Alternator and circuit breaker connections
14.
Unplug the connector from the emergency air shutoff relay if installed. (This is an option.) See
15.
Disconnect the yellow/brown wire from the air compressor’s temperature switch. See
switch, tee fitting, elbow fitting, and adapter