5 – Generator and Engine Components
6.
Position the front panel against the generator side of the unit. Disconnect the air pressure line from the air pressure
gauge or air tank if necessary. Route the wires for the 120 V and 480 V outlets under the generator. Removal of the
plasma supply sliding door may be necessary.
Figure 49
Reattach the front panel
1.
Place the front panel back in position. Secure with 2 screws near the base board. See
sure all the wires are connected securely on the back of the panel.
2.
Reconnect the air line from the air tank to the pressure gauge if detached.
3.
Reconnect the CPC connector to the front panel using the 4 screws and nuts.
4.
Put the system’s top cover and panels back in place. See
5.
Reconnect the negative (-) ground cable to the battery.
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...