2 – Routine Maintenance
Drain the condensate from the air tank
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Facing the plasma side of the system, make sure the
pressure release opening near the front corner of the base
is not obstructed. Air and condensate exit from the air tank
through this opening.
3.
Facing the front of the system, slowly rotate the lever so
that it is facing down. The lever is in the recessed cutout
under the generator. See
4.
When the air draining from the tank is clear, close the
valve by rotating the lever towards you until it is parallel
with the bottom of the system.
Figure 11
CAUTION!
Drain condensate from the compressed air tank to make sure the tank operates safely.
Condensation inside the tank causes corrosion over time and weakens the integrity of the tank walls.
Rotate lever down to drain air tank
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...