98
Freedom 38 PPA
Service Manual
809010
3 – System-Level Components
Replace emergency stop contact block
Remove the emergency stop contact block
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the top cover from the system. See
4.
Loosen the 2 screws
that secure the emergency stop contact block.
5.
Unscrew the terminals
from the contact block. Mark the locations in reference to the assembly.
Figure 30
Install the emergency stop contact block
1.
Connect the 2 terminal wires
to the new contact block.
2.
Secure the contact block to the emergency stop plate by tightening the 2 screws
.
3.
Put the system’s top cover back in place. See
4.
Reconnect the negative (-) ground cable to the battery.
Kit number
Description
Kit: Contactor for Emergency Stop button
1
2
1
2
2
1
Содержание Freedom 38 PPA
Страница 1: ...Freedom 38 PPA Large Autonomous Plasma Cutting System Service Manual 809010 Revision 0 English ...
Страница 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Страница 74: ...74 Freedom 38 PPA Service Manual 809010 2 Routine Maintenance Figure 18 Engine fuel filter Hand pump ...
Страница 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Страница 208: ...208 Freedom 38 PPA Service Manual 809010 7 Parts Figure 122 Air compression hose locations 1 2 3 4 5 6 7 8 9 5 6 7 ...
Страница 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Страница 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Страница 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Страница 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...