Page 53
9.7
Replacing Thermo Sensor (for Heater Ele-
ment)
Removal
»
Close off water supply.
»
Drain steam cylinder (9) by setting main switch to Pos
II.
»
Disconnect power supply and secure against restart
(switch off control switch, remove main fuse and control
fuse F1).
»
Verify absence of electric current.
»
Remove steam cylinder connector plug.
»
Remove star screw from the steam hose adapter (2).
»
Remove clip on steam hose adapter.
»
Push the steam hose adapter up out of the cabinet and
secure with clip.
»
Loosen clamping belt.
»
Lift steam cylinder out of the base (11).
Warning
: When lifting the cylinder be aware not to damage the
heating element cable.
»
Remove theating element cable from main plug.
»
Loosen clips of capillary tube.
»
Disconnect capillary tube from the heating elements
(8).
»
Remove the 2 srews from thermo sensor.