Page 52
9.6
Cleaning connection hoses, cylinder base
and nozzle
When operating with partially softened water or tap water scale
can be discharged with the steam flow and can settle in the noz-
zle (3) that is in the steam hose adapter. Therefore, this nozzle
should be tested regularly as part of the general maintenance
review and cleaned if necessary.
Installation
»
Install new heater element, replacing the parts in the
correct sequence according to the diagram, and screw
nut with a torque of 5Nm onto the pressure plate.
»
Insert the heater element’s connecting cable into the
two marked terminals and tighten. Polarity of (heater
element) connecting cable is not important.
»
If necessary: Install capillary tube on the thermo sensor
using retainer clips.
»
To proceed further, follow the steps described above in
section “Cleaning Coarse Strainer Cylinder Base.”