Remove cylinder base o-ring (13).
»
Lift strainer insert (12) out of the base using the two
access holes on the side.
»
Remove all deposits from the coarse strainer.
»
Keep coarse strainer clean with mechanical utilities.
»
Check base for deposits and remove if necessary.
Especially the passes of the hose connections should
be checked.
»
Insert coarse strainer and position correctly by clicking
the cut-out into place in the clip.
Assembly
»
Thoroughly clean o-ring seating in cylinder base. No
calcium residue can remain behind on the seating.
»
Moisten new cylinder base o-ring and insert in base.
»
Remove o-ring (4) from the steam hose adapter (2).
»
Moisten o-ring fluid and place on the upper part of the
cylinder collar on the cylinder cover (5).
»
If necessary, replace o-ring seal between cylinder (9)
and cylinder cover.
To do this:
•
Loosen clamping belt and lift off cover.
•
Remove o-ring (15).
•
Insert new o-ring, replace cover . Close clamping belt.
Warning:
To avoid harming fingers during closing of the clamp-
ing ring, make sure that your fingers are not in the closing range.
»
Push steam cylinder back into base with a gentle twist-
ing motion.
Warning:
When inserting the cylinder be aware not to damage
the heating element cable
Note:
The information sticker “hot surface” must be positioned at
the front.
»
With a gentle turning motion, put adapter (2) over the o-
ring on the steam outlet and fix it with the star screws.
»
Slide clip between adapter and cabinet.
»
Close clamping belt.