Page 57
»
Remove cylinder as described above in section “Clean-
ing Steam Cylinder.”
»
Seal off water supply and remove screw joint from fresh
water connection (L).
»
Detach connector hoses (G) from base (11) and mark a
position.
»
Remove electrical connectors from double solenoid
valve (H) and mark position.
»
Remove solenoid valve mounting screws (I).
»
Take the solenoid valve out of hole.
Cleaning
»
Remove fine mesh filter (K) from the solenoid valve and
clean.
Installation
»
Place solenoid valve with seal in the hole in the unit
cabinet.
»
Secure solenoid valve tightly with screws (I).
»
Attach fresh water connection (L).
»
Connect elecrical cable to the double solenoid valve.
Take care to position correctly.
»
Attach connector hose (G) to the base by using clamps
(M)..
»
Install cylinder as described above in section “Cleaning
Steam Cylinder”.